Cut the hours behind environmental lab data validation.
Automate the mechanical prep, and keep the professional judgment. Upload your laboratory report package to get back a page-cited review workpaper and an Excel workbook ready for sign-off, with every final decision left to your chemist.
Sample QA/QC: matrix-spike recovery
| Analyte | Spike | Native | MS result | Recovery | Limit |
|---|---|---|---|---|---|
| Dibenzothiophene | 1,310 | 7,600 | 7,440 | -13% | 40-125% |
| Pyrene | 1,310 | 40,700 | 37,100 | -282% | 47-127% |
Lab context: 40x dilution; Q-03, native concentration far above spike amount.
Source: Lab package pp. 33, 42, 124 · QAPP p. 59 Table 3-1
Sample receipt and preservation: holding time
Lab context: H-08 confirms hold extended at -18 C; 4 C time stayed under 14 days.
Source: Lab package pp. 42, 162-163 · QAPP p. 71 Table 4-2
Raw-quantitation recalculation
(138.69 ng/mL x 2 mL x 10) / (11.62 g x 0.7631 solids) = 312.81 ug/kg dry
Operands checked: Instrument response, sample mass, % solids, final volume, dilution factor.
Source: Lab package pp. 88, 394-395
What we check, and what stays with you.
LabDataReview handles the extraction, reconciliation, and arithmetic across Stage 2A-4 (Level II-IV) packages. Without a project QAPP, checks against laboratory-printed limits stay labeled VERIFIED or EXCEPTION, never project PASS.
| Stage | Checks we prepare | Stays with your chemist |
|---|---|---|
| Stage 2ASample QC |
|
Qualifier and reason code for each exception, and whether a lab explanation is acceptable. |
| Stage 2BInstrument QC |
|
Bias direction and which field samples an instrument failure affects. |
| Stage 3Recalculation & EDD |
|
Usability decisions wherever a recalculation or EDD discrepancy appears. |
| Stage 4Raw data prep |
|
Visual peak inspection of chromatograms and raw mass spectra. We never re-integrate peaks. |
What comes back
Three outputs from the same job: a workpaper for reading, a 5-tab workbook for qualifying, and structured findings for your systems.1
1. Review workpaper (PDF)
Print-first A4 workpaper ordered by chemist workflow: open completeness items first, receipt and holding times, sample QC, instrument checks, recalculations, and a concise review action index.
2. Qualification workbook (Excel)
Five-tab workbook keeping every uploaded EDD row and literal value verbatim (ND, <RL, leading zeros) alongside reconciled PDF findings, source pages, and blank validator dropdown columns (U, J, J+, J-, UJ, R, NJ).
3. Structured findings (JSON)
Machine-readable JSON with every check performed and unperformed, stage accounting, near-match diagnostics, and page or row source trails for LIMS or internal QA tooling.
| SampID | Analyte | Result | Units | LDR_ |
LDR_ |
Validator_ |
Reason_ |
Bias_ |
|---|---|---|---|---|---|---|---|---|
| A0A0740-33 | Pyrene | 40,700 | ug/kg | EXCEPTION MS rec. -282% | p. 124 | blank | blank | blank |
| A0A0740-33 | Dibenzothiophene | 7,600 | ug/kg | EXCEPTION MS rec. -13% | p. 124 | blank | blank | blank |
| A0A0740-12 | All analytes | See report | ug/kg | VALIDATOR DECISION Prep 27.85-30.65 d vs 14 d | pp. 162-163 | blank | blank | blank |
Upload a package
Free during the pilot, with no account required. Upload your files to get a private status link right away and an email when deliverables are ready.
- Laboratory report PDF (born-digital works best)
- Excel or CSV EDD (recommended, kept verbatim in workbook)
- Project QAPP or criteria PDF (optional, for project limits)
- Unzip folders before uploading; ZIP archives are not accepted
Do you have questions? Contact us.
Upload limits appear when this service is enabled.
Supported formats appear when submissions are available. Upload email attachments separately; ZIP bundles are not supported.
Built for
- Consulting teams
- Cut review bottlenecks and catch lab-to-EDD discrepancies, calculation errors, and QC exceptions before client or agency submittals.
- Independent validators
- Clear more SDGs while keeping full qualification and sign-off authority.
- Lab QA teams
- Run an automated pre-release check on report PDFs and EDDs before sending packages to clients.
Questions
How long does it take?
In most cases it is ready under an hour. We send a status email as soon as your deliverables are ready, and you can check progress anytime from the private job link returned when upload completes.
What packages and validation stages are supported?
LabDataReview prepares Stage 2A, Stage 2B, Stage 3, and Stage 4 checks across Level II, Level III, and Level IV packages. Covered matrices include water, soil/solids, sediment, air/vapor, and radiochemistry across common US and Canadian commercial lab formats, with or without an EDD.
Do you assign final data qualifiers?
No. We prepare objective checks, calculations, exceptions, source trails, and open completeness items. Final qualification flags, reason codes, bias directions, usability decisions, and visual chromatogram or mass-spectra inspection remain with your validator or project chemist.
What if there is no project QAPP?
When no QAPP or criteria document is supplied, comparisons against the laboratory's printed limits stay labeled VERIFIED or EXCEPTION rather than project PASS. Upload a project criteria PDF whenever you want project limits applied.
What files can I upload, and are scanned PDFs supported?
Upload born-digital laboratory report PDFs, accompanying .xlsx, .xls, or .csv EDDs, and optional project QAPP or criteria PDFs. Extract ZIP archives before uploading. Short scanned reports up to about 30 pages are supported, while large multi-hundred-page image-scanned archives are out of scope.
How is my data handled, and what if I mistype my email?
Most born-digital lab reports are processed deterministically without calling external processing services. When third-party commercial cloud services are used for scanned, degraded, or complex layouts, those providers do not use submitted files for training and retain requests only briefly for short-lived caching and automated abuse monitoring. During a job's retention window, LabDataReview may review submitted files to troubleshoot failures, address your feedback, and improve parsing accuracy. Files and deliverables expire automatically (7 days for incomplete drafts, 30 days for submitted jobs). Common email typos are flagged inline before upload, and your private job link opens right after upload finishes.
- Sample findings and workbook rows on this page are drawn from public laboratory package A0A0740. Actual workpaper and workbook coverage depends on the submitted files and criteria. Back